Sensor Controller series CA-S / CA-D


Freedom of flexible installation


Adjustable range 0 - 25 m
Hysteresis setting 10% / 22%
Timer functions
Signal Quality LED's
1 or 2 channels controllers

CA-S / CA-D description



The controller series CA-S / CA-D includes a 27 kHz modulator that ensures the TA10 transmitter and the RA10 receiver to be synchronised. As long as a merging in the phase & tact frequency is present the signal will be approved, and the controller indicates this way of the LEDs.
A change in the "tact" or a reduction in the signal size result in the output changing its status.
The CA-S / CA-D series controller is delivered with high setting convenience as it is equipped with LED indicators for voltage, signal quality, signal recognition and output condition. Furthermore, it has a infinitely variable reach adjustment, a change-over switch for short/long reach facillitating an expanded dynamic area, a NO/NC signal output and an on/off timer function adjustment.

Electrical data

Range, Adjustable "CA-S" SWL: 0-6 m / SW H: 0-25 m; "CA-D"SWL: 0-4 m / SW H: 0-20 m
Hysteresis Position SW L: 10%; Position SW H: 22%
Operation frequency 30 Hz Duty Cycle 50 %
Response time 20 mS / 20 mS
Signal status indicator Yellow LED
Signal detection indicator Yellow LED
Signal quality detector Green LED
Power on indicator Green LED
Serial / Parallel output switch Yes only on 2-channel model CA-D
Power Supply 14-30 VAC & 14-36 VDC; 115 VAC; 230 VAC (+/- 10%)
Power consumptions Max. 3,1 VA
Output Relay 1 NO / 1 NC; 250 VAC / 3 A; 115 VAC / 5A
Output Solid State Relay 1 NO ; 40 VAC / 150 mA; 40 VDC / 150 mA
Power start up delay 100 - 300 mS
Transmitter pulse frequency 27 kHz

Mechanical data

Connections 11 -pole DIN plug  
Housing material Noryl  
Sealing Class IP 40 IEC 529
Temperature, operation -20 - +55°C IEC 68-2-14
Temperature, storage -20 - +80°C IEC 68-2-14
Weight 200 gr. ( 230 & 115 VAC) 120 gr.(24 V AC/DC)  
Approvals CE / LVD EN 50082-2; EN 6.000-6-2
EN 60647
RoHS compatibel Yes