Sensor Transmitter TA10 & Receiver RA10

Freedom of flexible installation


Range 0 - 25 m
Cable lenght more than 100 m
Fully sealed IP 67
Foreign light immunity up to 60.000 Lux
Custom integration

Sensor System Description



The TA10 / RA10 series is an infrared transmitter and receiver unit in a small IP 67 sealed compact design. The sensors is connected to a controller series CA-S (Single channel) or CA-D (double channel). The sensors can be installed in reaches from 0 - 25 m and penetrate considerable amounts of dirt / dust besides being extremely insensetiv to external foreign light and electrical interferences. The sensor series TA10/RA10 is an ideel sensor to custom made solution.

Electrical data

Receiver " RA10"

Signal Bandwidths 10 - 70 kHz fc 30 kHz
Amplifications 80 dB 30 kHz
Color ID Yellow  

Transmitter "TA10"

Max DC Current 100 mA 25 °C
Max p.p. Current duty cycle=50% / 200 mA  
Max cable resistance 100 Ohm  
Color ID Red  

Optical data

Working range 0 - 25 m  
Max range 35 m  
Light wave length IR 880 nm, pulsed w. 27 kHz  
Light immunity 60.000 lux ‹ 20°
Optical angle ± 10° 50% Limit

Mechanical data

Sealing class IP 67 IEC 529
Temperature, operation (°C) -20....+60 IEC 68-2-14
Vibration 10 - 55 Hz 1,5mm pp IEC 68-2-14
Shock 30 G IEC 68-2-27
Housing Polycarbonate PC
Connection TA/Cable 2*0,25mm2 - RA/Cable 1*0,25mm2  
Max. Cable pull force Max. 60 N IEC 947-5-2
Standard cable length 5 or 15 m  
Max. Recommended length (TA) 100 m / (RA) 30 m TA10 / RA10
EMC Yes EN 60947-5-2
RoHS compatibel Yes